Macrium reflect unable to dismount volume. To successfully image and clone removable drives Macrium Reflect must first dismount the drive volume(s). Macrium reflect unable to dismount volume

 
 To successfully image and clone removable drives Macrium Reflect must first dismount the drive volume(s)Macrium reflect unable to dismount volume  This can be achieved using the Windows Disk Management Console to convert one or more physical disks to Dynamic

I'm sure this was working a couple of days ago! Mike: By dbminter - 25 November 2021 3:01 AM First thing I would try if you haven't yet is restarting the PC. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. An update will be made available shortly to resolve this problem. I use Macrium Reflect to create a bootable rescue disk on a USB fob and a full image of C: on an external hard disk. 1835 on Win 10 64 Pro, returns a. Changed Block Tracker This release fixes a problem with the previous release, v8. To find the VSS log, open Reflect > Logs > Double-Click the FAILED backup > VSS > Save. Or, press Win + X (hold down the Windows key and press X ), and choose Disk Management. ReflectUpdater. Click Keep Trial and choose Connect in This Computer to continue. Here is. Denying administrators from accessing volume roots can cause many unexpected failures, and will prevent VSS from functioning properly. What I want to do: 1 backup important files to an external (already done) 2 clone the NVMe to the HDD 3 pop the case, install the new NVMe, put it all back. I have a USB Hard Drive with the backup. That can persist even while the Reflect application is not running. only an option to create an image of the volume. To use Macrium Reflect to recover my laptop to a bootable state, I either use the aforementioned USB rescue fob or the Macrium boot menu option if one had been created. Press Windows + S, type “ command prompt ” in the dialogue box, right-click on the application and select “ Run as administrator ”. When Macrium Reflect attempts to dismount a volume, it needs exclusive access to it. 5283) did NOT solve the update problem. connect the new ssd to the computer (let' call it computer A), restart the computer, enter BIOS and and change boot order to try to boot from the new ssd. CryptoA Full image file contains all of the data stored in the volume. This has been resolved. Windows 7 Home Premium x64 SP-1. says: Solution 1 - Remove drive letters allocated unnecessarily to small partitions. Scroll down until you find "Macrium Reflect {Edition}", then select this entry and click the repair option. 31. Device Manager says:When Macrium Reflect takes an image, it invokes Volume Shadow Copy Service (VSS). I am trying to clone one external USB drive (14TB, 11TB full) to another external USB drive (18TB). But the problem still persists. Partitions are automatically resized to fill the cloned disk and are also aligned for optimum SSD performance and reliability. Select a volume by clicking the check box and then Click OK. The Reflect Default settings would cause old backup files to be purged without specifying --retention option. Result code 0x800703f7 Unable to match partiton. The clearest example of this is RAID 1, which mirrors. Log file: Logging initialized for viBoot Date Time Level TID File Line Function Description-----21-May-21 7:54:17 AM 3716 Logging started 21-May-21 7:54:17 AM Information 3716 e: elease-reflect-8imagevibootviboot. I've used the Browse function many times before - in fact it is one of the. Server Core Reflect was unable to launch on Windows Server Core due to missing 'oledlg. I could find no real fault with Casper but changed to Macrium Reflect because of its high profile and enthusiastic support in the IT community and its own active support via a Forum and direct support for licensed users. Macrium is a piece of software I hold dear as i've been using various editions of it since 2012. Installing Home breaks it again. would like to show you a description here but the site won’t allow us. 5" form-factor SSD). The system can’t unmount the disk you are currently booted from. There is an unfortunate gap of 50 GB between the OS partition and the recovery partition. Deletion by ID must specify a valid snapshot ID, deletion by volume must specify a valid Windows volume (e. mring. When you get the main interface of Disk Management, you can select the drive that you want to check and fix, then right-click it and choose Property. The "Microsoft software shadow copy provider" process has been using ~50% of the CPU for all this time and there are intermittent. Macrium Support Team. Go the Log tab in Reflect and see if you have a VSS Log, which is separate from the general job log that you posted as a screenshot. Changing vol letters as needed. Sure you have MIG against ransomware. Maybe Macrium Reflect actually successfully did the clone work though it tells you that it failed. It is a fast, strong, and flexible support game plan. Macrium unable to clone disk with unknown partitions Migrate a Cloned SSD to a same make and series but slightly later Laptop. By Mack - 27 November 2022 12:26 AM After uninstalling the fresh copy of Reflect Home now, Revo finds ~200 leftover registry keys and ~150 files in C:ProgramsMacrium still taking 22MB. The window is split into 2 parts, the upper concerns volumes and the lower disks. But the problem still persists. You can just point Reflect at the destination disk again and it will just ignore whatever is there when it reattempts the clone. 7638, tried multiple computers/SSDs but same issue. One of the long standing requests for Macrium Reflect is the ability to be able to image any system, regardless of whether Reflect is installed. Once run, a detailed log file will be created in the same directory as the VBScript source. Additionally, ejecting a device would eject all storage volumes that reside on that device, which may not be desirable. Generating scripts and batch files. Backup aborted - Failed to Create Volume Snapshot Not sure what to do to overcome this reported registry issue. Mike By dbminter - 25 November 2021 3:01 AM First thing I would try if you haven't yet is restarting the PC. I'm running W10/64 home and Macrium7. EXPAND - Expands the maximum size available on a virtual disk. Type “ select disk [disk number] ” to select the destination hard drive. The first thing you should do is create rescue media. US Customer Sales: (347)-565-5912. However whenever i try to clone macrium keeps saying “Dismount failed” and says that another drive is being used and that i have to run it in “Windows PE” I also tried using Minitool partition but it says that the system volume and boot volume are not on the same disk and that i can’t migrate it . Under the Other Tasks -> Edit Defaults menu, and under the Advanced tab, there is a Destination Drive Discovery option. Disk mirroring is the real-time replication of data from one logical volume to another separate disk. Exit Diskpart: exit. Then enter "clean". it says that Macrium Reflect is unable to dismount the volume. Press Win + R at the same time to launch the Run box. com Copying the base Wim from '?Volume{8a9bcf78-a5e8-11e1-863e-806e6f6e6963}. Details below: Machine 1 - Failed around 50% with 1 drive. Try CHKDSK /R rather than /F. Stale volume name meta data The volume name displayed in the Reflect restore and mount user interface would not reflect changes made after the Full image. 0 to v8. For the record, somewhere on this forum I put together script snippets that could be integrated into a Reflect-generated PowerShell script in order to mount a volume of a known, user-specified GUID before a backup and then dismount that volume afterward, but I think that predated Image Guardian, and I don’t have time to go looking for it now. 4228 will not allow me to browse my backup files. Macrium Reflect 8. Scroll down the list of disks in the lower pane. Click the dots and you'll have options to edit or delete the post. That was mounted and I then mounted the backup file. 2. The application refuses to make any changes to the. Exited diskpart and opened an admin shell. Type services. 1. Finally pulled the trigger on my first build. . Running an elevated command prompt. 30-Day Free Trial includes: Removable media imaging and cloning. But first, let’s delve into the problem of Macrium Reflect being unable to dismount a volume. Note: Removable media does not support the creation of Microsoft Volume Shadow Copies. BitLocker Encrypted restore/clone The volume is restored/cloned in a BitLocker locked state and can be unlocked using the source volume password (or TPM chip). I'm trying to use Macrium Reflect to transfer the data and programs from the old prebuilt's HDD to. Then, to be sure, first restart after uninstalling Reflect. msc and press Enter. A screen image and copy of the clone definition file is attached. A user reports an error on installing Macrium Reflect V8 on Win11 when trying to dismount an image of a volume. You don't necessarily need a PC to be a member of the. So the Macrium uninstaller is very poor. Open comment sort options Best; Top; New; Controversial; Q&A; Add a Comment. Failures must be located and fixed for disk images and file backups to complete. A problem started occurring right after I upgraded his SSD from a Samsung SM961 M. I click unmount and I get a box with a label saying drive but not drive H: or any other drive to select for unmounting. If so,. Download and install Macrium Reflect (or Samsung Data Migration, if a Samsung SSD) If you are cloning from a SATA drive to PCIe/NVMe, install the relevant driver for this new NVMe/PCIe drive. Restarted. Run the Macrium Reflect (or Samsung Data Migration) Select ALL the partitions on the existing C drive. Disconnect ALL drives except the current C and the new SSD. The appropriate context menu entry is not displayed. Please screenshot/copy out the result and attach it to your reply. 2 512GB (NVMe) to a Samsung 860 EVO SATA M. I am unable to boot. 0/5. "According to Macrium's Support page here, the Home version of Reflect does not offer support renewal beyond the 12-month period included with the license purchase. Check for active FAT32 partition in removable media. I tried to cloning to new disk with Macrium Reflect but always got an error, the same goes for imaging. I am able to copy the OS partition to the target drive, but no matter how much space I have left, I can not copy the recovery partition to the. In terms of time, you have about 220 GB of data and you’re working with an HDD, so figure maybe 100 MB/s, so figure about 40 minutes. If you have a problem mounting your images, it is possible that the image mounting system driver has failed to load correctly. . When this option is selected I. Disconnect ALL drives except the current C and the new SSD. The errors could be various, you just need to try the solutions we bring. Applies to: Macrium Reflect v5, all editionsThe disk is unable to read the requested block. I tried rebooting the laptop. I recently bought an SSD to clone my windows 10 OS to the new SSD from my HDD. Step 3. 7675. ⚫ Windows 가 Microsoft VSS(Volume Shadow Copy Service)를 사용하여 실행되는 동안 Windows System 및 데이터를 SK 하이닉스 SSD 에 복제하여 '특정 시점' 의 데이터 정확성을 보장할 수 있습니다. Why is Macrium Reflect unable to dismount a volume? A1. 1/4. 19 Feb 2020 #12. Help. Thanks in advance. This creates a backup that results in a consistent restore. Can use something like Mini Partition Tool to move unallocated space next to. Download and install Macrium Reflect (or Samsung Data Migration, if a Samsung SSD) Power off. 1909 PC, Ext2Fsd failed, but DiskGenius successfully mounted the partition. Installing Macrium Reflect from the command line. #Macrium reflect unable to dismount volume windows# Press Windows + R, type “ command prompt” in the dialogue box, right-click on the application and select “ Run as administrator”. Many users of Macrium reflect back up their data to usb-hdd. Step 2: Type Disk Utility in the search field. 0. Drive / Volume: To utilise this space, Windows will typically assign a letter, at which point it will become visible in the windows explorer. If you use Rescue Media that doesn’t have an auto-unlock key for the volume (s) of interest, you need to open Command Prompt from the taskbar and use the manage-bde utility to unlock volumes. I continue getting the notice at the Window PE process-----> "Unable to lock drive "The following drive is in use and the restore cannot continue: c [Volume(long REFLECT file)\)" Now, after shutdown and restart (with no external drives attached) I am presented with the recovery screen asking if I wanted to boot into Windows 10 or the Macrium recovery media. 1. In the main window of Macrium Reflect, select Existing Backups, then select the Image tab. 1. With the help of Microsoft Volume Shadow Copy Service,. Select the image you wish to mount then click the Browse icon. Restore non-booting systems. Initial Macrium Reflect v7. This has been resolved. SQL Server is a VSS-aware application. Volume detection Reflect would fail to recognise file systems formatted on Dynamic volumes spanning disks with 4K sector sizes. I only have the default Windows Security as my AV. Boot with the Macrium USB drive, and use it to delete the partitions from the new SSD and have it write the image you made earlier to the new SSD. Using Macrium Reflect from the command line. Method 1: Right Steps to Unmount Volume for Repair on Disk Utility. Rescue media files will now be stored on that volume, any existing Macrium Reflect rescue media files from previous builds will be moved to a newly. "Volume Shadow Copy Service warning: VSS was denied access to the root of volume ?Volume{5921af20-d1dd-11ec-a026-ecf4bb3250da}. 7175 Crack is a strong reinforcement utility for. The first time I tried cloning the OS, I booted the PC up on the SSD alone and it worked wonderful! Super fast. Generating scripts and batch files. When you've selected a drive or folder that contains a. Volume detection Reflect would fail to recognise file systems formatted on Dynamic volumes spanning disks with 4K sector sizes. Following some videos I’ve seen, I downloaded Macrium…Similar to extend volume in the Disk Management, you can use it to extend the current partitions with unallocated space, it has two options, namely, "Add unused space to all partitions" or "Manually adjust partition size". Share Sort by: Best. 0 User Guide. 1 Open This PC in File Explorer (Win+E). Or you'd find a link to it in the Installing Macrium Reflect KB article here. dll' module. Reply Like 0. Technician’s License: Reflect as a portable application. The operation took about 22 hours to complete. Much of the interface text is also shown in italics, and then there's the taskbar at the bottom with various buttons, including the camera button I mentioned. Note: The X in the above commands represents the number of your Target drive. I'm really stuck here. Select the image you wish to mount then click the Browse Image link. This article explains how Reflect enables you to resolve these situations. Ĥ) Restart. Macrium Reflect uses Microsoft VSS (Volume Shadow Services) to create snapshots. If you do not want to modify the order or size of partitions of the clone, click Next. Or you could have just Googled "Macrium. 2486: By jphughan - 4 February 2023 11:57 AM A mounted volume means that a Reflect backup is mounted as a virtual disk for. You can try Macrium Reflect's VSS repair tool and see if that helps. Type “ list disk ” to show all the disks connected to your computer. Source volume(s) on removable media will therefore be dismounted when this Image stats, and open file handles. Macrium V8. txt. The source drive is 465gb and the target drive is 447gb. Drac144:. I have no idea what or how to 'dismount' mounted volumes! I did try closing all running programs/apps, etc. Unfortunately these behaviours perhaps suggest Macrium reflect is perhaps neither? I'll not be buying a licensed version with these behaviours unless they can be adequately explained. My issue isn't on this list. If you have another hard drive (like for game or picture storage), boot the Macrium USB and create an image of your current SSD to it. I suspect that the Acronis Cleanup Tool has damaged VSS or possibly another supporting service (s). Turn off. Reflect 8 Home Trial. Was having Reflect enable booting to Reflect if there was a problem. Reply Like 0. What is the next best steps. 2, Build 3957 on a Win 10 64 bit system. Macrium Reflect 8. That’s usually cleaner than posting the. exe. Right-click the volume, and choose. Macrium Reflect 8. Where d is operating system volume, E is efi volume, you have to assign a drive letter. DETACH - Detaches a virtual disk file. msc and hit Enter. Copy the /boot/macrium contents to the USB root folder. When you load Reflect from USB, click on the command line prompt and run. That can persist even while the Reflect application is not running. This drive was cloned with Macrium and now is in a new computer (I had do re-activate Windows, etc. There may be multiple Volumes on one disk. 1. See our reviews on. On one Win10 machine here, using a Free installation (6. 31. Assigned a drive letter with assign letter=E. Does Macrium Reflect support RAID The short answer is, yes, Macrium Reflect supports RAID. Computer says external drive is working okay. Macrium Reflect can create Full, Differential, and Incremental images to optimize backup speed and disk space requirements. D: [Volume] - Unable to dismount volume Help Hello, I am trying to clone my Drive Windows (C:) to Local Disk (D:) , and I am using Macrium Reflect to do that. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright. I got an external hard drive and created a clone of my C drive using Macrium Reflect. Topics. Online Help Keyboard Shortcuts Feed Builder What’s new Available Gadgets About Confluence Log in. Correcting errors in the Volume Bitmap. From Dec 23 Update Release Notes 7. Macrium Reflect Failed to create volume snapshot . Spaces; Hit enter to search. How to Clone a Hard Disk Drive, SSD, NVME (NVM Express) in Windows 10 the Free and Easy way. Right click on 'My Computer'. Troubleshooting. So the Macrium uninstaller is very poor. Tried disabling KTS2020 but to no avail. See our reviews on. Additionally, it can be turned off by clicking on an NTSF volume in Reflects main window and accessing the Actions drop-down menu. Tag: macrium reflect unable to dismount volume. Go back to the post and notice the 3 dots in the upper-right corner. Solution 3 - Remove old VSS snapshots. 1. Changing the startup type of the VSS service and rebooting can often resolve issues. dll' module. If a volume with a drive letter was imaged, but the volume GUID path couldn't be found, this would incorrectly complete the image with a 'pssnap' message in the log. Created by Scott Arden-Jones on Mar 16, 2015; Go to start of metadataThe cause of this is usually that a Macrium Reflect component is missing or unable to run. This can be achieved using the Windows Disk Management Console to convert one or more physical disks to Dynamic. Select the clone target disk. Mapped network shares not visible in Macrium Reflect when UAC is enabled. This has been resolved. Then select the drive of the mounted image (in this case F: drive), right click and then select Unmount Macrium Image as highlighted in red. You may also see an event similar to the following in the Windows event log:Backup aborted! - Unable to lock volume; Scheduled task save failed: The system cannot find the path specified;. To do that, you would open Reflect, go to Backup Definition Files, right-click your definition file, and select Run Now > Prompt. Open Macrium Reflect and attempt to explore the ext4 partition. Macrium Reflect creates an accurate and reliable Image of a hard disk or the partitions on the disk. Disconnect ALL drives except for the new SSD. Go to USERs/YOURUSERID/ and all your documents, pictures, desktop, etc. This is especially relevant when a file system contains very large files, such as virtual hard disk. 2 Answers. If you have updated from an earlier release of Macrium Reflect, and backup drives have been protected. Hi all, So I just built a new rig. To invoke, from the start menu select run, or in the "search programs and file" field, type diskmgmt. Edit: I also reinstalled Macrium Reflect as well, same issue Locked post. ERROR: COM call "m_pVssObject->BackupComplete (&pAsync)" failed. Server Core Reflect was unable to launch on Windows Server Core due to missing 'oledlg. On the Macrium Reflect item in the dropdown list there is no option to dismount. • 25 days ago. 1. Using Macrium Reflect Command Line Interface (CLI) to mount an image. x) will be perpetual for the life of Macrium Reflect 8. Page 1 of 3 - Macrium Refect can't 'see' my C:drive in Windows 7 64-bit - posted in Backup, Imaging, and Disk Management Software: I have just done a clean install of Win 7 Pro SP1 and fully. Both drives are in a Western Digital MyBook Duo enclosure that Windows sees as two separate drives (no RAID setup). D:\ [Volume] - Unable to dismount volume Help Hello, I am trying to clone my Drive Windows (C:) to Local Disk (D:) , and I am using Macrium Reflect to do that. These are all being backed up to. there are file errors on the drive - without actual bad sectors then they are sometimes caused on windows 10 by the use of third party maintenance tools. 2 nvme pcie ssd. Typically customers see "the parameter is incorrect" or no mounting whatsoever. Then, Boot your PC from the Installation Media you just created (change Boot Order in your BIOS) to begin installing Windows 10. 2 NVME SSD into my computer, and today I swapped out my old 256 GB SSD that came with the computer (a Lenov. 2 Answers. Step 1. Cloned to an NVMe M2 SSD and won't boot. Backup Scripting. Restart the backup task. Click Refresh to read the newly initialized disk. By dbminter - 19 July 2020 8:36 PMReflect has an option that (should) fix the issue of imaging a disk with bad sectors. The “Virtual Machines” view (1) , displays the name of the viBoot created virtual machine, the current state of the virtual machine (Off, Running, etc). On Windows XP, you may. Support and Maintenance for Business Users. 2. I have a computer running windows 10 that has a few issues with the HDD. I changed to the Google public DNS servers and was able to reach the Macrium download servers. If your whole system becomes corrupt, you can load Macrium Reflect and restore your image despite being unable to boot Windows. 2. Macrium Reflect Server Plus for Exchange and SQL. This means that any open files currently accessing the volume(s)€ on the flash drives being. With new hard drive connected to same server but not as part of a windows storage spaces volume, we have success albeit with a catastrophic VSS. Unmount ISO or IMG file using Eject. Macrium Reflect can create Full, Differential, and Incremental images to optimize backup speed and disk space requirements. Open a command prompt and change the directories as necessary so the path to. In Reflect, select your source disk and click "Clone this disk". this new ssd has some stuff on it but i do not care if. Now, as can be seen in the below screenshots, the Disk Image is only C or only D. I have a USB Hard Drive with the backup. And THEN you click Refresh under Reflect's Backup tab, AFTER you have altered the state of your disk (s) -- not before as you surmised. This has been resolved. To fix this issue see here: VSS Fails due to. 3. This article explains a possible solution for the following error displayed in an image backup log: Backup aborted! - Unable to read from disk - Error Code 121 - The. Any imaging or restoring can then be. 33 TB Image Guardian: Protected Free space threshold: Delete oldest backup sets when free space is less than 50. Switch to the Advanced tab, click the uppermost Settings button, switch to the Advanced tab in there, and click the Change button. then you will see the following message box the first time Macrium reflect is started:I have been trying to clone the hard drive from a laptop onto a new, higher capacity drive which is in an external caddy. How do I clone my Macrium Reflect hard drive to SSD. Macrium Reflect v8. Result code 0x800703f7 Unable to match partiton. In most cases this won't cause any problems, Explorer will gracefully close, for example, however, please. Result Code: 0x80042306. What I want to do: 1 backup important files to an external (already done) 2 clone the NVMe to the HDD 3 pop the case, install the new NVMe, put it all back together 4 clone the HDD to the new NVMe. ". You may also see an event similar to the following in the Windows event log:The cause of this is usually that a Macrium Reflect component is missing or unable to run. Additionally, we will provide answers to 14 common questions related to this issue at the end of the article. Windows Image File (WIM) and toolset files location. I get all the proper dialogs, but when I click the C: image to browse nothing happens other than a 5 sec. I have booted to a macrium generated boot disk. If I confirm the "Restart" button, the following message apperars on the top of the window: "Dismounting drives - Dismount failed - Checking and Buliding PE Rescue Media" (see the added file) I have already updated the boot menu under "Other Tasks" - "Create Rescue Media". Adding 2 bad clusters to the Bad Clusters File. Run CHKDSK to check & repair source disk errors that might cause Macrium Reflect clone failed issue. Share More sharing options. )bcdboot d:windows /s E: /f UEFI and boot is fixed. The first time I tried cloning the OS, I booted the PC up on the SSD alone and it worked wonderful! Super fast. Returning to Reflect Free fixes this. 4063 om Windows 7 and can't create USB Rescue Media. . To successfully image and clone removable drives Macrium Reflect must first dismount the drive volume (s). In this example, only the C partition is restored to the target disk. However, the 18TB cloned drive is now not accessible. Disable pagefile from both (C:) and (R:) before cloning, then enable again once running from the destination. Tried uncheck verify image or backup file directly after creation, in Reflect Defaults and Setting > Backup Defaults > Auto Verify Image. I tried opening and closing Reflect. The log file: Open handle to physical drive: . To successfully image and clone removable drives Macrium Reflect. This has been resolved. DETAIL - Provide details about an object. Select 'Clone this disk' and walk through the steps to put the same partitions onto the SSD. Q1. How to upgrade your laptop with a SSD. The service dialog is shown. Macrium Reflect's Feature List and Feature Comparison Chart. By shaneh890 September 20, 2022 in Storage Devices. Backup Aborted! - Unable to lock volume. ) I have cloned the c: hard drive to an external SSD using Macrium, which works fine. more. Note 2: Users of the viBoot. Macrium Reflect Failed to create volume snapshot . I'll write this out as clearly and simply as I can here: Open Reflect. Reply Like 0. I click unmount and I get a box with a label saying drive but not drive H: or any other drive to select for unmounting. New OS using the code from the prebuilt Dell sticker to upgrade to Windows 10. Links appears below the selected disk. Macrium Unable to dismount volume Fix. Macrium Reflect adalah perangkat lunak pencitraan disk dan cadangan untuk Microsoft Windows yang membuat cadangan dan gambar menggunakan layanan Microsoft Volume Shadow Copy Service. We can use the utility ‘diskpart’ to clean the structure of your destination drive and see if this fixes the problem. . -> got message saying Reflect is up to date. BitLocker Removal restore/clone The file system is restored/cloned in the clear and BitLocker must be manually re-enabled on the restored/cloned volume to. My issue isn't on this list. Macrium Reflect uses shadow storage space for system restore points. Reply Like 0. By default Macrium Reflect only copies used sectors when making an image file, unless you are using the “forensic” mode which copies all sectors. 7638, tried multiple computers/SSDs but same issue. 3. Note 1: viBoot only supports Microsoft’s Hyper-V running on a minimum of Windows 8. After trying just the Macrium Rescue builder, I followed the guide in the knowledge base wiki that said to 1. 1 / 3. Logging file changes for Incremental and Differential Images. Then select the drive of the mounted image (in this case F: drive), right click and then select Unmount Macrium Image as highlighted in red. Select the disk to clone from in the main application window and click Clone this disk. Now there's the old stuff from the old HDD from the prebuilt. DELETE - Delete an object. If you open the Computer Management application (just search that name under Start) and then click Disk Management, you can remove drive letter assignments. This should fix the problem in most case. In the target disk area, click Select a disk to clone to and select the SSD disk. PC Master Race - PCMR: A place where all enthusiasts of PC, PC gaming and PC technology are welcome! Welcome to the official subreddit of the PC Master Race / PCMR! All PC-related content is welcome, including build help, tech support, and any doubt one might have about PC ownership.